Subject: [Elecraft] Measurements TX
Date: Fri, 12 Feb 1999 15:08:25 +0100
From: "Peter Zenker" <Peter_DL2FI@csi.com>
Made some measurements at the TX Load: 50 Ohm Adjusted power rate at K2: 5Watt Test Equipment: HM5006 Analyzer (0-500 MHz) results should be exact within a 2 dB failure rate Band Harmonic Spurs 3560 btr -55 dBc na 7030 bttr -55dBc na 10100 bttr -55 dBc na 14060 bttr -55 dBc na 18100 bttr -55dBc na 21060 bttr -50dBc -46dBc at 11MHz 24900 bttr -50dBc -46 dBc at 15 MHz 28,060 bttr -50dBc -43 dBc at 18 MHz will be continued 72 de Peter DL2FI